Industry solution · Energy & industry

Insulating oils.
Operationally reliable. Standard-compliant. Continuously cared for.

Transformers and switchgear are not serviced like vehicles — their oil is conditioned. IEC 60422 specifies what must be maintained. Fine filtration based on the FLOWLOGIC principle works continuously towards it — automatically, without interrupting production.

IEC 60422 · DIN VDE 0370 Target: water content < 10 ppm Breakdown voltage > 70 kV No oil change — oil care
Note on the information on this page
The calculations, limit values and example values shown are for general information only and are non-binding. They are based on published technical sources, standards (including IEC 60422) and our own model calculations under simplified, typical assumptions. Depending on the measuring method, operating conditions, oil and equipment type and scientific approach, results may differ and interpretations may vary. The information does not constitute a guarantee of specific properties or results in any individual case and replaces neither the prescribed tests nor the expert assessment of the respective installation.
Evidence from practice
As early as 1992, an energy supplier used the filters with great success to clean insulating oil in 110 kV and 20 kV circuit breakers. Since then, an oil replacement there has only been necessary in exceptional cases.
Tested by TÜV Bayern Sachsen (1993), also for transformer oil: particle and water content decrease with every filter pass, and the oil is not chemically altered.

Suppliers of insulating oils deliver exactly what they are commissioned to deliver: a product that meets the standard and specification. What happens to it inside the transformer — over years, under load, with moisture ingress — lies outside their scope of supply.

That clean, dry insulating oil insulates longer than moist oil is undisputed. The logical step was always: recondition or replace the oil manually — with costs, downtime and risk. Rarely did anyone ask whether there was another option.

There is. Insulating oil can be cared for continuously and thus kept within the standard — without interrupting operation.

FLOWLOGIC is nothing more and nothing less than the answer to a question that was never asked in the established procedure. An addition that had long been missing — almost unnoticed, almost self-evident. And on top of that, with a return that can be calculated and verified.

Physics · Electrical insulation · Water

Why water in insulating oil is no small matter

A few ppm of water — that sounds like nothing. But physics is mercilessly non-linear. What is still safe at 10 ppm becomes a danger to the equipment, the grid and insurance cover at 60 ppm.

Insulating oils in transformers and switchgear perform two tasks at once: electrical insulation and heat dissipation. Water destroys both functions — and it inevitably forms: through ageing, temperature fluctuations and humidity. The breakdown voltage does not fall linearly but disproportionately fast.

// Durchschlagspannung vs. Wassergehalt — physikalische Näherungsbeziehung U_d ~ 1 / √(c_H₂O) // U_d = Durchschlagspannung [kV] · c_H₂O = Wasserkonzentration [ppm] // Beziehung ist stark nichtlinear — kleine Wassermengen, große Wirkung // Zusätzlich: SO₂/NOₓ aus Ölalterung + Wasser → H₂SO₄ → greift die Isolation an Weniger Wasser — weniger Mineralsäure — weniger Gefahr für die Isolation
Water contentBreakdown voltageConditionWhat it means
< 10 ppm> 70 kVNew oil / idealGoal of continuous filtration
10–30 ppm50–70 kVStandard metMonitoring recommended
30–60 ppm35–50 kVBorderline rangeInitiate drying — still manageable
> 60 ppm< 35 kVCriticalImmediate action — risk of breakdown

The problem with manual reconditioning: Water forms continuously — through breathers, ageing seals and temperature changes. Manual reconditioning is a reaction to a measurement result. Fine filtration based on the FLOWLOGIC principle acts as a constant counterforce — it removes water continuously, before the limit value is reached. Reactive maintenance becomes continuous protection.


IEC 60422 · DIN VDE 0370 · Compliance

The standard sets the rules — fine filtration works continuously towards them

Operators of transformers and switchgear are obliged by standards to monitor their oil. The limit values leave no room for interpretation. Anyone who fails to comply risks shutdown by the grid operator, loss of insurance cover and personal liability.

ParameterNew oil (target)Operation OKLimit value / actionContribution of fine filtration
Breakdown voltage (kV)> 70> 50< 30 → immediatelyWater removal targets > 70 kV
Water content (ppm)< 10< 30> 50 → dryingTarget: < 10 ppm
Acid number TAN (mg KOH/g)< 0,01< 0,1> 0.3 → checkWater removal slows the rise in TAN
Dissipation factor tan δ (90 °C)< 0,001< 0,01> 0.05 → criticalRemoval of particles and water stabilises it
Particle content ISO 4406< 15/13/10< 17/15/12> 19/17/14 → filterFiltration down to < 1 µm

Conclusion

Fine filtration acts on all five IEC parameters at once — continuously, without manual intervention. Target: water content well below the IEC limit, particle class below 15/13/10. TAN rise measurably slowed by interrupting the acid formation pathways. Compliance turns from an event into ongoing care. The prescribed oil monitoring remains in place.


Costs · Risks · Return

What a failure costs — and what FLOWLOGIC costs

Transformers are not serviced every day. They run — until they don’t. Then it is not just the repair price that counts. Everything that follows counts.

8–15 T€
Manual oil reconditioning
per cycle · 10,000 L transformer
6 figures
Consequential damage costs
in the event of unplanned shutdown
0
Production interruptions
due to FLOWLOGIC operation
Target < 10 ppm
Water content well
below the IEC limit

Concrete calculation — 10,000-litre transformer

Manual reconditioning every 2–3 years: €8,000–15,000 per cycle (special equipment, downtime, logistics, analysis costs).
With FLOWLOGIC: reconditioning cycles can largely be eliminated — as early as 1992, an energy supplier reported that an oil replacement was only necessary in exceptional cases.
Example calculation over 10 years: 3–5 cycles saved ≈ €24,000–75,000 in direct savings.
In addition: a significantly lower risk of unplanned failures, insurance claims and liability.

For insulating oils, fine filtration is not just a cost saving — it is risk prevention with a return that can be calculated and verified.


Same operation · Further applications

Anyone who operates transformers usually operates something else as well.

Operational reliability is no coincidence.
It is a decision.

IEC 60422 sets the limit values.
Fine filtration based on the FLOWLOGIC principle supports you — continuously, automatically, without intervention.
Not as a reaction. As a permanent state.

Order filters → Calculate savings